    • WYH series poultry house heating hot air stove (click to enter)
    WYH series poultry house heating hot air stove (click to enter)

    Category:Other devices

    • 售后QQ: 點擊這里給我發消息
    • 售后QQ: 點擊這里給我發消息
    Hotline:+8615864583687
    Details

    WMHChicken coop composite hot air stove

    Compound heating: using two methods of tube heating: flue gas and hot air. Both methods consume all the heat50%about. This unique heating technology combines the advantages of two heating methods.

    Smoke duct: The length starts from the furnace and runs through the entire chicken coop. Set in the span of the chicken coop1/4—1/3The location. Center height of flueone point fiveMeter, diameterthree hundredMade of zinc sheet.

    Air duct: length from the furnace to the back of the chicken coop5-10Mi, set in the middle of the chicken coop span or slightly towards the other end. The height of the air duct is generally within1.8-2.5Between meters. diameterfour hundredfrontfifteenRice is made of zinc plates. The back is made of canvas. both sidesone hundred and twentyThe downward angle of the air outlet is staggered and dispersed.

    Main technical parameters

    model

    Rated heat generationkj/h

    Hot air volumeM3/h

    Heating areaM2

    Air outlet temperature Celsius

    Overall thermal efficiency%

    Rated coal consumptionKg/h

    Experienced coal consumptionKg/g

    Fan power introduction+Hoodkw

    WMH30

    one million two hundred and fifty-five thousand

    eight thousand

    one thousand and four hundred

    one hundred and fifty

    95%

    forty-two

    twelve

    3+0.75

    WMH40

    one million six hundred and seventy-two thousand

    ten thousand

    one thousand and eight hundred

    one hundred and fifty

    95%

    fifty-eight

    fifteen

    4+0.75

    Note:oneThe rated coal consumption refers to the theoretical amount of coal required to reach the rated heat generation.

    twoThe experience of coal consumption refers to the use of standardized insulation, raising commercial chickens, rice husks for flat farming, and outdoors-15Celsius degrees1-3The chick rearing area has reachedthirty-fivecentigrade. Breeding periodforty-fiveThe hourly average coal consumption of the entire batch of chickens in the day.

     

    WMHDual air self-control energy-saving hot blast stove

    1. The heat and flue gas generated by coal combustion are absorbed and utilized within the limits of air through more scientific and reasonable multi pass heat exchange technology, resulting in120-150The hot air in Celsius provides heat for livestock and poultry, while the temperature of the flue gas is effectively controlled withineightyBelow Celsius degrees.
    2. Because the air is directly heated and sent into the building without water, there is no risk of scale or ice formation, and there is no need to install a separate radiator, so there is no need for secondary heat exchange. And the glass wool insulation layer that comes with our furnace body also minimizes the loss of heat, thereby achieving an overall heat utilization rate90%above.
    3. High temperature heat exchange part inside the road hall-Heat resistant tube, manufactured using our factory's anti erosion technology, capable of long-term durabilityone thousand four hundred and fiftyUse at high temperatures of Celsius without damage.
    4. At the same time. This anti erosion technology also solves the problem of high-temperature corrosion of steel, greatly improving the trouble free operation period of the hot blast stove3-5Year, the overall service life has reachedeightYears or more.

    Main technical parameters


    model

    Rated heat generationkj/h

    Hot air volumeM3/h

    Heating areaM2

    Air outlet temperature Celsius

    Overall thermal efficiency%

    Rated coal consumptionKg/h

    Experienced coal consumptionKg/g

    Fan power introduction+Hoodkw

    WMH10

    four hundred and eighteen thousand

    three thousand and eight hundred

    five hundred

    one hundred and fifty

    90%

    fifteen

    five

    two

    WMH15

    six hundred and twenty-seven thousand

    five thousand and six hundred

    seven hundred and fifty

    one hundred and fifty

    90%

    twenty-two

    nine

    1.5x2+0.55

    WMH20

    eight hundred and thirty-six thousand

    eight thousand

    one thousand

    one hundred and fifty

    90%

    thirty

    twelve

    2.2x2+0.55

    WMH25

    one million and forty-five thousand

    nine thousand

    one thousand and two hundred

    one hundred and fifty

    90%

    thirty-six

    fourteen

    3x2+0.55

    WMH30

    one million two hundred and fifty-five thousand

    ten thousand

    one thousand and four hundred

    one hundred and fifty

    90%

    forty-two

    sixteen

    3x2+0.55


    Note:oneIn addition to the commonly used specifications mentioned above, larger models of hot air stoves can also be produced.

    twoTheWMHThe air volume of the hot air stove is the output air volume of the dual fan hot air stove.

    threeThe rated coal consumption refers to the theoretical amount of coal required to reach the rated heat generation.

    fourThe experience of coal consumption refers to the use of standardized insulation, raising commercial chickens, rice husks for flat farming, and outdoors-15Celsius degrees1-3The chick rearing area has reachedthirty-fivecentigrade. Breeding periodforty-fiveHourly average coal consumption of the entire batch of chickens in the sky